Combination IO Modules

8DIN+8DO Ethernet Remote IO Module

Item No.: M140
M140 Ethernet Remote I/O Module comes with 8DI, 8DO, RS485, RJ45, the Remote I/O module supports SNMP V1/V2, Modbus TCP server and client, Modbus RTU master and slave, and MQTT protocol.
  • T Version: 1*RJ45+1RS485+8DI+8DO
  • E Version: 2*RJ45+1RS485+8DI+8DO
  • Introduction Features Specifications Download Applications
    M140 Ethernet I/O Module
    M140 Ethernet Remote I/O Module comes with 8 digital input, 8 digital output, RS485 serial port, RJ45 Ethernet port, the Remote I/O module supports SNMP V1/V2, Modbus TCP server and client, Modbus RTU master and slave, and MQTT protocol. The remote I/O module can be integrated into SCADA and other industrial automation systems, and also can be connected with cloud platform for remote monitoring and remote control.
     
       8DI
    Wet contact/Dry contact
    High speed pulse counting
     
     
    8DO
          SINK 
    Pulse output
     
                                             


    Item Parameter Description
    Power Input voltage
    1. Models without AO: 9~36VDC
    2. Models with AO: 24~36VDC
    Power consumption Typical standby power consumption: ≤ 2W
    Power Output
    1. 1 channel
    2. Output voltage: 936V DC
    3. Output current: 1500mA@12V(MAX)
    Protection Reverse wiring prevention;
    ESD Air: 15KV; Surge: 4KV
    Ethernet Specification 1 x RJ45, 10M/100Mbps
    Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
    Protocol Modbus RTU, Modbus TCP, MQTT
    Serial port QTY 1 x RS485
    Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
    Data Bit 7, 8
    Parity Bit None, Even, Odd
    Stop Bit 0.5, 1, 1.5, 2
    Protocol Modbus RTU(slave), Modbus RTU(master)
    Protection ESD contact: 8KV  Surge: 4KV(8/20us)
    Digital input QTY 16 channel(Max)
    Type Support Wet contact(NPN, PNP) and Dry contact.
    Default: Wet contact
    Dry contact
    1. Close: Short circuit
    2. Open: Open circuits
    Wet contact
    1. Close: 10~30VDC
    2. Open: 0~3VDC
    Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
    Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
    Isolated protection 2KVrms
    Sampling Rate 100Hz
    Digital output QTY 16 channels(Max)
    Type SINK
    Capacity 500mA per contact
    Overvoltage protection 50VDC
    Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
    Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
    Protocol conversion Support Modbus TCP and RTU protocol conversion
    Support Modbus RTU to MQTT and Modbus TCP to MQTT
    Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
    User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
    Map data bool: 300
    Description
    M140 Ethernet I/O Module
    M140 Ethernet Remote I/O Module comes with 8 digital input, 8 digital output, RS485 serial port, RJ45 Ethernet port, the Remote I/O module supports SNMP V1/V2, Modbus TCP server and client, Modbus RTU master and slave, and MQTT protocol. The remote I/O module can be integrated into SCADA and other industrial automation systems, and also can be connected with cloud platform for remote monitoring and remote control.
     
       8DI
    Wet contact/Dry contact
    High speed pulse counting
     
     
    8DO
          SINK 
    Pulse output
     
                                             


    introduction
    Features
    Specifications
    Item Parameter Description
    Power Input voltage
    1. Models without AO: 9~36VDC
    2. Models with AO: 24~36VDC
    Power consumption Typical standby power consumption: ≤ 2W
    Power Output
    1. 1 channel
    2. Output voltage: 936V DC
    3. Output current: 1500mA@12V(MAX)
    Protection Reverse wiring prevention;
    ESD Air: 15KV; Surge: 4KV
    Ethernet Specification 1 x RJ45, 10M/100Mbps
    Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
    Protocol Modbus RTU, Modbus TCP, MQTT
    Serial port QTY 1 x RS485
    Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
    Data Bit 7, 8
    Parity Bit None, Even, Odd
    Stop Bit 0.5, 1, 1.5, 2
    Protocol Modbus RTU(slave), Modbus RTU(master)
    Protection ESD contact: 8KV  Surge: 4KV(8/20us)
    Digital input QTY 16 channel(Max)
    Type Support Wet contact(NPN, PNP) and Dry contact.
    Default: Wet contact
    Dry contact
    1. Close: Short circuit
    2. Open: Open circuits
    Wet contact
    1. Close: 10~30VDC
    2. Open: 0~3VDC
    Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
    Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
    Isolated protection 2KVrms
    Sampling Rate 100Hz
    Digital output QTY 16 channels(Max)
    Type SINK
    Capacity 500mA per contact
    Overvoltage protection 50VDC
    Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
    Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
    Protocol conversion Support Modbus TCP and RTU protocol conversion
    Support Modbus RTU to MQTT and Modbus TCP to MQTT
    Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
    User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
    Map data bool: 300
    Download
    Applications